Many Zoeller sump pumps and sewage pumps are manual / non-automatic pumps which are made automatic with a float switch or a control panel. Dean Bennett Supply is a stocking distributor for Zoeller sump pumps and sewage pumps and the accessories that go with them, like float switches.
Many float switches are single ball float switches that are a piggyback design. Piggyback float switches plug into the power wall outlet, and the manual pump plugs into the back of the float switch plug. The float is tethered to the discharge pipe from the pump, to control the on and off points.

 

ZOELLER
Float Switches

 

DEAN BENNETT SUPPLY
Independent Zoeller Pump Distributor
Toll Free   1-800-621-4291
 

 

 
  BE SURE TO ASK ABOUT OUR ZOELLER
LOYALTY REWARDS DISCOUNT

 
 
 

 PUMP DOWN to EMPTY TANK   FLOAT SWITCHES

The Pump Down to Empty Tank control is used with sump and sewage pumps. We stock these variable level float switches in the piggy-back plug-in design. The float switch plugs into the outlet and then the pump plugs into the piggy-back switch. These plugs are wired for either 115 volt or 230 volt use and all come with a 15' cord.
These variable level float switches are mechanically activated and DO NOT CONTAIN MERCURY to avoid any environmentally sensitive concerns.
The single ball switch has only one float that controls both the on and off function of the pumping range.
The double ball float switch has two floats. One that turns the pump on and one that turns the pump off, which allows for a much wider range of on and off levels.
Single ball switches can be direct wired by cutting off the plug.
Double ball float switches MUST be used with the plug. DO NOT CUT THE PLUG OFF THE DOUBLE BALL FLOAT SWITCH.

The States of CT, RI, ME, IL, VT, MN, NY, MA, & CA can not use mercury floats - must buy special floats
 

Float switch controls water level by turning on or off a pump.

Piggy back float switches plug in and the pump plugs into the back of the switch plug.

100034 115v 13 amp single ball float switch for sewage pumps.
100034 115V 13 Amp
Single Ball Float Switch
with 15' power cord.

100033 230V 15 amp single ball float switch.
100033 230V 15 amp
Single Ball Float Switch

#10-0034
No Mercury
$   39.60 115 Volt Junior Single Ball Float Switch Control has a 15' cord with a piggy-back plug for use with up to 13 amps maximum.
 
#10-0032
No Mercury
$   64.80 115 Volt Super Single Ball Control for 15 amps maximum has a 15' cord with a  piggy-back plug. Must be used with #140, #163 and #270 Zoeller Pumps.
 
#10-0706
No Mercury
$   47.70 230 Volt Single Ball Float Switch Control for 13 amp maximum, with 20' cord and piggy-back plug.
For use with #293 Zoeller Pumps
 
#10-0033
No Mercury
$   70.20 230 Volt Super Single Ball Float Switch Control has a 15' cord with a piggy-back plug for up to 15 amps maximum.
 
DOUBLE BALL FLOAT SWITCHES
Double Ball Float Switches are used to have a tighter control of the on and off points.
 
#1016864
No Mercury
$ 118.00 115 Volt Mechanical Double Ball Float Switch for pump down. 15' piggy-back plug. 13 amp maximum.
 
#10-0229
Mercury Switch
Use #
1016864
 
 
#1017657
No Mercury
$ 121.00 230 Volt Mechanical Double Ball Float Switch for pump down. 15' piggy-back plug. 13 amp maximum.
 
#10-0230
Mercury Switch
 
Use #
1017657

 
     

100032 115v 15 amp single ball float switch for sewage pumps.
100032 115V 15 Amp
Single Ball Float Switch
with 15' power cord.

SJE #1016864 115V double ball float switch.
SJE #1016864 Double Ball Float Switch

hanger bracket for float switches or sensor floats
4 Float Hanging Bracket for sensor and float switches.
Sensor float with plug on end. Float switch with no plug to har wire a pump system.
 
 
PUMP UP to FILL TANK   FLOAT SWITCHES

The Pump Up to Fill Tank controls serve just the opposite function as described above and are used to turn a pump off when cistern or tank is full. We stock these in open end ( without plug ) for direct wiring purposes. Since there is no plug, they can be used for either 115 volt or 230 volt use. All come with 15' cord. These variable level float switches are mechanically activated and DO NOT CONTAIN MERCURY to avoid any environmentally sensitive concerns.
 

 
Cable Weights are used to control the positioning of the sensor float in a sewage basin.
Cable Weight for float switches and sensor control floats
#1002725
  $ 49.75
No Mercury
Junior Single Ball Float Switch Control, without plug for use with up to 13 amps maximum. Can be used for either 115 volt or 230 volt direct wiring.

JUNIOR SWITCHES are for pumps up to 1/2 hp at 115 volts or 1 hp at 230 volts drawing a maximum of 13 amps.
 

#1003253
  $ 69.00
No Mercury
Super single Ball Float Switch Control, without plug for use with up to 15 amps maximum. Can be used for either 115 volt or 230 volt direct wiring.

SUPER SWITCHES are for pumps up to 3/4 hp at 115 volts or 2 hp at 230 volts drawing a maximum of 15 amps.
 

SENSOR FLOAT CONTROLS are used to signal a control panel.
Variable Level Control Switch is normally open when hanging vertically above the liquid level.
Switch closes when it reaches a few degrees above the horizontal position.

Variable Level Control Switches are constructed of durable PVC/polypropylene encasing the variable level switch. Standard mechanical variable level control switches are rated for 115V/230V power at 5 Amps. Can be used in temperature of water up to 140 degrees F.
 

#10-0744
  $ 32.40
No Mercury
 
Non-Mercury sensor float for panels is normally open control used with control panels.
100744 float switch has a 20' cord.
Normally open means the float is normally open when hanging down.
#01-1832
  $ 32.40
No Mercury
 
Identical to the 10-0744 Float Above with 20' cord.
#10-1878
  $ 46.80
No Mercury
 
Non-Mercury sensor float for panels is normally open control with 35' open end cord, used with control panels and is rated 5 amp max.
#10-0225
 
Use #
10-0744
Above.
 
 
#1002152
  $ 46.75
Mercury
Activated
 
#15-SWE-NO normally open sensor is the same as above except it has an external adjustable weight attached to the cable. It is used in any application where the float is suspended from
above, rather than being attached to the pipe.
#1006047
  $ 33.50
No Mercury
Sensor float switch with 15' open end cord that is normally closed. Rated 5 amps at either 115 volt or 230 volt. Float is not weighted, but comes with pipe tie clamp to control alarm
activation level. Drinking Water rated for low water alarms.
 
#100329
$ 249.50
 
3 Float Switch Assembly with brackets and weights.
# 100347
$ 165.75
 
3 Float System for #840 Grinder package
 
 

 

 

Sensor float switch to control a pump on and off level.
  BE SURE TO ASK ABOUT OUR ZOELLER
LOYALTY REWARDS DISCOUNT

Zoeller Home Page        Contact us

Zoeller Effluent Sump Pumps         Zoeller Sewage Pumps        

Zoeller "BEST BUY" Pumps           Zoeller Sewage Basins

Zoeller Grinder Type Sewage Pumps           Zoeller Check Valves

Zoeller Packaged Sewage Systems           Zoeller Control Panels

DEAN BENNETT SUPPLY Home Page


 

Prices effective October 1, 2013